The pump is designed to transfer watery gas-saturated salable oil in the pipeline gathering systems, processing and oil transfer systems.
       It can be used
1) for transferring water with pH=7-8,5, the contents of mechanical impurities not more than 0,2% and the size of solid particles not more than 0,2mm. The temperature of the transferred water is from 1 to 45° C.
2) for pressure testing of oil system and feeding oil to the controlling system at starting and stopping of the turbogenerators. The working fluid is turbine oil T22 with temperatures 50-55° C.
Flow rate, m3/h | 180 |
Head, m | 212 |
Power, kW | 148 |
Height of self-suction, m | 6 |
Frequency, rpm | 1475 |